Explosion proof suction fan, BT axial flow fan, cooling fan, Shanghai Yipai brand
Explosion proof suction fan, BT axial flow fan, cooling fan, Shanghai Yipai brand










BT35-11 Explosion proof Axial Flow Fan BT35-11-5Explosion proof axial flow fans are suitable for transporting flammable, explosive, and non corrosive gases. The ambient temperature should not exceed 60 ℃, and they are widely used for ventilation and heat dissipation in general factories, warehouses, offices, and residential areas. They can also be installed in series with long exhaust pipes to increase the pressure in the pipes. After removing the motor, they can be used as a free fan. The anti-corrosion axial flow fan (FT35-11 type) is made of anti-corrosion materials coated with epoxy paint, and the motor uses a special anti-corrosion motor for transporting corrosive gases. Explosion proof axial flow fan (BT35-11 type), used for transporting flammable and explosive gases. The impeller is made of aluminum alloy to prevent sparks during operation, and the motor adopts explosion-proof type. The performance parameters and external dimensions of FT35-11 and BT35-11 fans are the same as those of T35-11 fans. The fan needs to be equipped with bracket feet and motor voltage. Please specify when placing an order.
Installation Instructions for BT35-11 Explosion proof Axial Flow Fan BT35-11-5
1. Before installation, the fan should be carefully inspected for any damage or deformation. If there is any damage or deformation, it should be repaired properly before installation can proceed.
2. When installing the BT35-11-3.55 explosion-proof axial fan, attention should be paid to checking whether the connecting parts are loose, and the gap between the blades and the air duct should be uniform and not collide.
3. The weight of the connecting air duct should not be borne by the air duct of the fan, and additional support brackets should be added during installation.
4. A collector must be installed at the air outlet of the fan, and it is recommended to install a protective net.
5. The fan base must be naturally connected to the foundation plane, and it is not allowed to forcefully connect the base by knocking it to prevent deformation. During installation, the base should be calibrated, iron pads should be added, and the basic horizontal position should be maintained. Then, the anchor bolts should be tightened.